Pro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (2024)

Contents hide

1Pro1 Technologies T705 Programmable Thermostat

2Thermostat Operation

2.1Set Program Schedule 5+1+1 or 7 Day (Continue…)

3Warranty Information

4Reference

Pro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (1)

Pro1 Technologies T705 Programmable Thermostat

Pro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (2)

Pro1 Technologies
P.O. Box 3377
Springfield, MO 65808-3377
Toll-Free: 888-776-1427
Web: www.pro1iaq.com
Hours of Operation: M-F 9 AM – 6 PM Eastern

Caution:
Equipment damage hazard. Do not operate the cooling system if the outdoor temperature is below 50 ˚F (10 ˚C) to prevent possible compressor damage.

Thermostat Operation

Pro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (3)

  1. LCD Display
  2. Glow in the dark light button
  3. Fan Switch
  4. System Switch
  5. Temperature Setpoint Buttons
  6. User Buttons
    • LCD Display
      See page 4 for details about this display readout.
    • Glow in the dark light button
      The glow-in-the-dark light button will self-illuminate for several hours after exposure to ambient light. This button turns on the display light when pressed.
    • Fan Switch
      Select ON or AUTO. ON will run the fan continuously. AUTO will cycle the fan on only when the heating or cooling system is on.
    • System Switch
      Selects the operation mode on your HVAC system. Selecting HEAT turns on
      the heat mode. Selecting COOL turns on the air conditioning mode. Selecting OFF turns both heating and cooling off.
    • Temperature Setpoint Buttons
      Press the + or – buttons to select the desired room temperature.
    • User Buttons
      Use these buttons to set up your programming options. Refer to the next page for detail.

Caution: When the battery is Pro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (4)LOWon appears replace your AA batteries immediately. Failure to do so may result in your heating & cooling system becoming inoperable. Freezing or overheating can occur.

Pro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (5)

Important: The low battery indicator is displayed when the AA battery power is low. If the user fails to replace the battery within 21 days, the screen will only show the low battery indicator but maintain all functionality. If the user fails to replace the batteries after an additional 21 days (days 22-42 since the first “low battery” display) the set points will change to 55˚F(Heating) and 85˚F(Cooling). If the user adjusts these setpoints away from these it will hold for 4 hours and then return to either 55˚F or 85˚F. After day 63 the batteries must be replaced immediately to avoid freezing or overheating because the thermostat will shut the unit off until the battery is changed.

Battery Door Information

Pro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (6)

Temporary and Permanent Hold Feature (if using programming)
Temporary Hold: The thermostat will display HOLD and RUN SCHED on the left of your screen when you press thePro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (7) orPro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (8) key. If you do nothing, the temperature will remain at this setpoint temporarily until the next time period. Your program setpoint will then replace your temporary setpoint. Permanent Hold: If you press the HOLD key at the left of your screen, you will see HOLD appear below the setpoint temperature in the display. The thermostat will now permanently stay at this setpoint and can be adjusted using the Pro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (9)orPro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (10) keys. To return to the program: Press the RUN SCHED key at the left of your screen to exit either temporary or permanent hold. If your HVAC contractor has configured the thermostat to remind you when the air filter needs to be changed, you will see FILT in the display when your air filter needs to be changed. Resetting the filter change reminder: When the FILT reminder is displayed, you should change your air filter and reset the reminder by holding down the second button from the top left side of the thermostat for 3 seconds.

Pro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (11)

Set Time

  1. With the system switch set to OFF, press the MENU button
  2. Press SET TIME
  3. The day of the week will be flashing. Use thePro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (12) orPro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (13) key to select the current day of the week.
  4. Press NEXT STEP
  5. The current hour is flashing. Use thePro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (14) orPro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (15) key to select the current hour. When using 12-hour time, make sure the correct a.m. or p.m. choice is selected.
  6. Press NEXT STEP
  7. Minutes are now flashing. Use the Pro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (16)or Pro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (17)key to select current minutes.
  8. Press DONE when completed.

Set Program Schedule 5+1+1 or 7 Day

  1. Select HEAT or COOL with the system switch. Note: You have to program heat and cool each separately.
  2. Press the MENU button (If the menu does not appear first press RUN SCHED)
  3. Press SET SCHED. Note: Monday-Friday or (Monday if in 7 Days) is displayed and the WAKE icon is shown. You are now programming the waketime period for that day.
  4. Time is flashing. Use the Pro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (18)or Pro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (19)key to make your time selection for that day’s WAKE time period.
  5. Press NEXT STEP
  6. The setpoint temperature is flashing. Use thePro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (20) or Pro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (21)key to make your setpoint selection for that day’s WAKE time period.
  7. Press NEXT STEP
  8. Repeat steps 4 thru 7 for that day’s LEAVE time period, RETURN time period and SLEEP time period

Set Program Schedule 5+1+1 or 7 Day (Continue…)

Programming The Thermostat
You can also use these time-saving functions. You must be in Set Sched Programming Mode (Press Menu >> Press Set Sched) for the following functions to work:

  1. To copy ALL time periods and temperatures of the current system and day to ALL days, Press and Hold the 2nd button down on left until the Days and Time flash.
  2. To copy ALL time periods (only times) for ALL days to the opposite system (Heat to Cool / Cool to Heat), Press and hold the Glow in the Dark Light button down until Set Time and Time flash.
    Repeat steps 4 through 7 for the Saturday WAKE time period, LEAVE time period, RETURN time period, and for the Saturday SLEEP time period.
    Saturday:
    Repeat steps 4 through 7 for the Sunday WAKE time period, LEAVE time period, RETURN time period, and for the Sunday SLEEP time period.
    Sunday:
    If using 7-Day Programming use the previous steps for every individual day.

Warranty Information

Warranty Registration
Your new thermostat has a 5-year limited warranty. You must register your thermostat within 60 days of installation. Without this registration, the warranty period will begin on the date of manufacture. For warranty issues please contact the HVAC professional that installed this product. You can register your new thermostat in 2 ways: Go to the company website, select warranty registration, and fill out a short registration form. Complete the form below and mail it to the address shown.

Warranty Registration

  • Thermostat Model:
  • Date Installed:
  • Complete the form and mail it to Thermostat Warranty Registration Pro1iaq
  • P.O. Box 3377
  • Springfield, MO 65808-3377 Cut Out For Warranty Registration www.pro1iaq.com

Reference

Download Manual:

Pro1 Technologies T705 Programmable Thermostat Operational Manual

OTHER MANUALS

Pro1 Technologies T705 Programmable Thermostat Installational Manual

Pro1 Technologies T705 Programmable Thermostat Product Specifications Guide

Pro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (22)

Pro1 Technologies T705 Programmable Thermostat Operational Manual

Pro1 Technologies T705 Programmable Thermostat Operational Manual - thermostat.guide (2024)
Top Articles
Latest Posts
Article information

Author: Clemencia Bogisich Ret

Last Updated:

Views: 5428

Rating: 5 / 5 (60 voted)

Reviews: 91% of readers found this page helpful

Author information

Name: Clemencia Bogisich Ret

Birthday: 2001-07-17

Address: Suite 794 53887 Geri Spring, West Cristentown, KY 54855

Phone: +5934435460663

Job: Central Hospitality Director

Hobby: Yoga, Electronics, Rafting, Lockpicking, Inline skating, Puzzles, scrapbook

Introduction: My name is Clemencia Bogisich Ret, I am a super, outstanding, graceful, friendly, vast, comfortable, agreeable person who loves writing and wants to share my knowledge and understanding with you.